Commands Listed in Alphabetical Order
Syntax
WFMOutpre:ENC
dg {ASCii| BINary}
WFMOutpre:ENCdg?
Related Commands
DATa:ENCdg, WFMOutpre:BYT_Nr, WFMInpre:FILTERFreq,
WFMOutpre:BIT_Nr, WFMOutpre:BN_Fmt
Arguments
ASCii specifies that the outgoing data is to be in ASCII format. Waveforms
will be sent as
<NR1> numbers.
BINary specifies that outgoing data is to be in a binary format whose further
specification is determined by WFMOutpre:BYT_Nr, WFMOutpre:BIT_Nr,
WFMOutpre:BN_Fmt and WFMInpre:FILTERFreq.
Examples
WFMOUTPRE:ENCDG? might return :WFMOUTPRE:ENCDG BIN indicating that
outgoing waveform data will be sent in binary format.
WFMOUTPRE:ENCDG ASC specifies that the outgoing waveform data will be sent
in ASCII format.
WFMOutpre:FILT ERFreq? (Query O nly)
Returns the FilterVu low pass filter frequency applied to the LRL waveform record
of the source waveform specified by DATa:SOUrce.IftheDATa:RESOlution is
set to FULL, then this is the filter frequency applied to the full resolution (LRL)
waveform. If the DATa:RESOlution is set to REDUced, then this is the filter
frequency applied to the reduced resolution (thumbnail) waveform.
Group
Waveform Transfer
Syntax
WFMOutpre:FILTERFreq?
Examples
WFMOUTPRE:FILTERFREQ? might return :WFMOUTPRE:FILTERFREQ
200000000
indicating that the FilterVu frequency for the outgoing waveform
is 200 MHz.
WFMOutpre:NR_Pt? (Query Only)
Returns the number of points for the DATa:SOUrce waveform that will be
transmitted in response to a CURVe? query. The query command will time
out and an error will be generated if the waveform specified by DATa:SOUrce
is not turned on.
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-367