Display Waveform Data
5. Select the desired style from the resulting
side-bezel menu.
Use the Full graticule for quick estimates of
waveform p arameters.
Use the Grid graticule for full-screen
measurements with cursors and automatic
readouts whe n cross h airs are not nee ded.
Use the Cross Hair graticule for making quick
estimates of waveforms while leaving mo re
room for automatic readouts and other data.
Use the Frame graticule with automatic
readouts and other screen text w hen display
features are not needed.
Quick Tips
You can display IRE and mV graticules. To do this, set the trigger type to video and set the vertical scale to 114 mV/division.
(The 114 mV/division selection is available in the coarse vertical scale settings for the channel when you set the trigger type to
video.) The oscilloscope will automatically display the IRE graticule for N TSC signals, and the mV graticule for other video
signals (PAL, SECAM , HDTV, and custom).
166 MSO4000 and DPO4000 Series Oscilloscopes User Manual

Table of Contents

Other manuals for Tektronix DPO4032

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO4032 and is the answer not in the manual?

Tektronix DPO4032 Specifications

General IconGeneral
BrandTektronix
ModelDPO4032
CategoryTest Equipment
LanguageEnglish

Related product manuals