Pinpoint trigge
rs
Trigger Type Trigger Condit
ions
Comm Trigger with m
ask testing on communications codes and standards (analog channels
only). The controls work together to define the parameters for the trigger event
(availablewithOptionMTMorMTHonsomeinstruments). This mode includes clock
recovery. Pus
h the Push to Set 50% knob to reinitialize clock recovery.
Bus
Trigger on co
mponents (such as a specified address) of a bus that you define.
With some instruments and options, trigger types include parallel, SPI, RS-232,
USB, and I
2
C triggers.
Not recomme
nded with iCapture inputs if using more than one source or an external
trigger.
Video
Trigger on specified fields or lines of a composite video signal (DPO7000C,
MSO5000B, and DPO5000B Series only). Only composite signal formats a re
supported
.
CAN Trigger o
n CAN Bus signals.
Not recommended with iCapture inputs if using more than one source or an external
trigger.
MSO/DPO70000DX, MSO/DPO70000C, DPO7000C, and MSO/DPO5000B Series User Manual 73