Appendix C
Table 3: Certications and com pliances
Characteristi
cs
Description
EC Declaratio
nof
Conformity
Compliance wa
s demonstrated to the following specication as listed in the Ofcial Journal
of the European Communities:
Low Voltage Directive 2006/95/EC:
EN61010-031
/A1: 2008
Category Examples of
Products in this Category
CAT III Distributi
on-level m ains, xed i nstallation
CAT II
Local-level mains, appliances, portable equipment
Measuremen
t Category
Descriptions
CAT I Circuits n
ot directly connected to mains.
Pollution Degree 2 Do not operate in environments where cond–
uctive po
llutants may be present (as dened in IEC 61010-1). Rated for indoor use only.
Additio
nal Safety S tandards
UL61010-031, 2010.
CAN/CSA
-C22.2 No. 61010–31/A1:2008
IEC61010-031;IEC 61010–31/A1:2008
Equipment Recycling. This product complies with the European Union’s requirements according to Directive
2002/96/EC on waste electrical and electronic equipment (WEEE). For more information about recycling
options, check the Support/Service section of the Tektronix Web site (www.tektronix.com).
Safety summary
Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as specied. Using the probe or accessories in a manner not specied
could result in a s hock or re hazard.
To avoid re or personal injury
Ground-Referenced oscilloscope use. Do not oat the reference lead of this probe when using with ground
referenced oscilloscopes (for example, DPO, MSO, and TDS series oscilloscopes). The reference lead must be connected to
earth potential (0 V).
Connect and disconnect properly. Connect the probe output to the m easurement instrument before connecting the
probe to the circuit under test. Disconnect the probe input and the probe reference lead from the circuit under test before
disconnecting the probe from the measurement instrument.
Avoid electric shock. To avoid injury or loss of life, do not connect or disconnect probes or test leads while they
are connected to a voltage source.
Observe all terminal ratings. To avoid re or shock hazard, observe all ratings and markings on the product. Consult
the product manual for further ratings information before making connections to the product.
Avoid electric shock. When using probe accessories, never exceed the lowest rating of the probe or its accessory,
whichever is less, including the measurement category and voltage rating.
MSO/DPO70000DX, MSO/DPO70000C, DPO7000C, and MSO/DPO5000B Series User Manual 185

Table of Contents

Other manuals for Tektronix DPO7054C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO7054C and is the answer not in the manual?

Tektronix DPO7054C Specifications

General IconGeneral
BrandTektronix
ModelDPO7054C
CategoryTest Equipment
LanguageEnglish

Related product manuals