Operation
Quick Tips
Push the Displays button on the front panel to open the Select Displays dialog box.
To add a display, double-click the icon.
To remove displays, do one of the following:
Select a display icon in the Selected Displays list, and then click Remove.
Double-click a display icon in the Selected Displays list.
Click the Close button in the upper right hand corner of the selected display.
You can mix displays from multiple application folders.
Common Information Messages
The following table lists some of the common information messages that might appear during normal operation.
Table 3 : Common information messages
Message Explanation and recommended action
Acq BW too small for current setup
The displ
ay needs a wider acquisition bandwidth than the current data record
contains. This can be due to any of the following reasons:
A display other than the one you intended has been selected. The selected
display has requested a smaller acquisition bandwidth to achieve a better
accurac
y or dynamic range for its particular measurement.
Select the display that contains the message. Click Run if the instrument
is not already acquiring data.
Acquisitions are not running and the measurement now requests a wider
bandwi
dth than the last acquisition.
Click Ru n to perform a new acquisition with a wider bandwidth.
The data is from a recalled le.
There is no way to increase the acquisition bandwidth for saved data. You
must a
djust the measurement settings so that less bandwidth is required.
Need swept acq or larger Acq BW When any display requires a swept acquisition, the other displays are unable to
proc
ess the swept data. This is because the swept data is customized for the
selected display.
Select the display that you are interested in and the acquisition settings will
auto
matically change to meet the requirements of the selected display.
RBW increased to 100 kHz
The
current Spectrum Length or Analysis Length is not long enough to allow
a narrower RBW lter.
If the Length control is set to Manual, try increasing it or setting it to Au to so
tha
t the Analysis Length will increase to the required value.
32 RSA6100A Series & RS A5100A Series Quick Start User Manual

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix RSA6114A and is the answer not in the manual?

Tektronix RSA6114A Specifications

General IconGeneral
BrandTektronix
ModelRSA6114A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals