EasyManuals Logo
Home>Tektronix>Test Equipment>T922

Tektronix T922 User Manual

Tektronix T922
217 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
Fig
.
2-2
.
Rear
panel
controls
and
connectors
.
Bottom
of
Cabinet-T921/T922
only
(see
Fig
.
2-4)
@
120
V/240
V-Screwdriver
actuated
switch
selects
either
120
V
or
240
V
nominal
power
input
voltage
.
WARNING
To
avoid
electric
shock
and
equipment
damage, do
not
attempt
to
replace
the
infernal
fuse
or
change
the
settings
of the
power
input
range
selector
switch or
HI1LO
switch
.
This
mustbe
done
by
qualified
service
personnel
only
.
@
HI/LO-Screwdriver
actuated switch
selects
either
high or
low
nominal
power-input-voltage
regulating
range
:
LO
selects
100
V
or
220 V and
HI
selects
120
V
or
240
V
.
REV
.
B
APR
1977
Operating
Instructions-T921/T922/T922R
@
CH
1
DC
BAL-Screwdriver
adjustment
.
When
properly
adjusted,
prevents
trace
shift
when
switching
between
adjacent
positions
of
the
CH
1
VOLTS/DIV
switch
.
CH
2
DC
BAL-Screwdriver
adjustment
.
When
properly
adjusted,
prevents trace
shift
when
switching
between
adjacent
positions
of
the
CH
2
VOLTS/DIV
switch
.
FrontPanel
(Fig
.
2-5)
B
.
VERTICAL
AMPLIFIER
O
VOLTS/DIV-Selects
the
vertical
deflection
factor
in
a
1-2-5
sequence
(VAR
control
must
be
in
detent
position
to
obtain
the
indicated
deflection
factors)
.
Read
the
correct
deflection
factor for
a
1X
probe
from
the
1X
position
and
a
10X
probe
from
the
10X
position
.
O
VAR-Provides
continuously
variable
uncalibrated
deflection
factors
between
the
calibrated
steps
of
the
VOLTS/DIV
switches
.
Extends
the
maximum
deflection
factor
to
25
V/div
in
the 10
V
position
.
Detent
position
provides
calibrated
VOLTS/DIV
deflection factors
.
Input
Coupling-Selects
the
method
of
coupling
the
input
signal to
the
vertical
input
signal
amplifier
.
AC
:
Signals are
coupled
capacitively
.
Any
do
signal
component
is
blocked
.
Low
frequencies
are attenuated
(3
dB
down
at
about
1
Hz
using a
10X
probe)
.
Ac
coupling
causes
tilting
of
square
wavesbelow
about
1
kHz
.
GND
:
Grounds
the
input
of
the
vertical
amplifier
to
provide
a
ground
reference
display
.
Connects
the
input
signal
to
ground
through
the input
coupling capacitor
and
a
1
Mil
resistor to
allow
the
input
coupling
capacitor
to
be
precharged
by
the
input
signal
.
DC
:
All
components
of
the
input
signal
are
passed
to
the
vertical
amplifier
.
Channel
1 or
Y
Input-Connector
for
applying
an
external
signal to
the
vertical
deflection
system
.
Provides the
Y
input
in
the
X-Y
mode
when
CH
1
vertical
mode
button
is
in
.
O
Channel
2
Input-Connector
for
applying
an
exter-
nal
signal to
the
vertical
deflection
system
.
2-3