PERFORMANCE
CHECK
This
procedure
allows the
basic
performance
specifications
to
be
checked
without
removing
theinstrument
covers
.
It
is
intended
for
use
in
incoming
inspection
to
determine
acceptability
of
newly
purchased
or
recently
calibrated
instruments
.
Tolerances
given
are
for
the
instrument
under
test
and
do
not
include
test
equipment
error
.
Limits
and
tolerances
in
this
check
are
instrument
specifications
only
if
they
are
called
out as
performance
requirements
in
the
specifications
section
.
'Requires
a
TM500
Series
Power
Module
.
REV
.
B,
DEC
.
1976
LIMITS
AND
TOLERANCES
TABLE
3-1
Test
Equipment
Section
3-T921/T922/T922R
TEST
EQUIPMENT
REQUIRED
You
will
need
the
test
equipment
listed
in
Table
3-1,
or
equivalent,
to
perform
a
complete
Performance
Check
of
the
T921, T922,
and
T922R
.
The
Specifications
given
for
the
equipment
are the
minimum
necessary
for
accurate
results
.
Examples
of
Applicable
Description
Minimum
Specifications
Usage
Test
Equipment
1
.
Amplitude
Calibrator
Amplitude
accuracy,
within
Vertical
Gain
checks,
a
.
Tektronix
PG
506
Calibra-
0.5%
;
signal
amplitude,
10
mV
X
gain
check
.
tion
Generator
.'
to
10
V
;
output
signal,
1
kHz
square
wave
.
b
.
Tektronix
067-0502-01
Calibration Fixture
.
2
.
Sine-Wave
Generator
Frequency
50
kHz
to
above
Vertical
Amplifier
band-
a
.
Tektronix
SG
503
Leveled
15
MHz
;
output
amplitude
width
checks,
X
bandwidth
Sine-Wave
Generator
.'
variable
from
0
.5
to
5
V
p-p
;
check
.
Triggering
checks
.
output
impedance,
50
0
;
Z
axis
input
check
.
b
.
Tektronix
Type
191
Cons-
reference frequency,
50
kHz
;
tant
Amplitude
Signal
amplitude
accuracy,
constant
Generator
.
within
0
.3%
of
reference
frequency
as output
frequency
changes
.
3
.
Time-Mark
Generator
Marker
outputs,
20 ns
to
0
.5
s
;
Timing
checks
.
a
.
Tektronix
TG
501
Time-
marker
accuracy
within
0.5%
;
MarkerGenerator
.'
trigger
output
1
ms
to
0
.1
has,
time coincident
with
markers
.
b
.
Tektronix
2901
Time-Mark
Generator
.
4
.
Termination
Impedance,
50
f2
;
BNC
Signal
termination
.
a
.
Tektronix
Part
011-0049-01
.
connectors
.
5
.
Cable
(3)
Impedance
50
i2
;
BNC
Signal
interconnection
.
a
.
Tektronix
Part
012-0057-01
.
connectors
.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix T922 and is the answer not in the manual?

Tektronix T922 Specifications

General IconGeneral
BrandTektronix
ModelT922
CategoryTest Equipment
LanguageEnglish

Related product manuals