EasyManuals Logo
Home>Tektronix>Test Equipment>T922

Tektronix T922 User Manual

Tektronix T922
217 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #79 background imageLoading...
Page #79 background image
REV
.
AJUL
1977
T922R
LINE
VOLTAGE
AND
RANGE
SELECTION
When
you
change
the
line
voltage
range,
be sure
you
change
the
position
of
the
screw
on
the
AC
RMS
RANGE
indicator
on
the
rear
panel
.
In
the
T922R,
the
Line
Selector
(120V/24OV)
and
Range
Selector
HI/LO
switches are not
accessible
outside the
instrument
.
To
change
the
settings,
remove
the top
cover
and
set
theswitches
according
to
the
available
line
voltage
(see
Fig
.
5-15)
.
See
the
Specifications
in
Section
1
of
this
manual
for
the
ranges
.
T922R
Z-Axis
Input
Polarity
Selection
Jumper
plug
P2430
may
be
installed
on
the
All
5
Buffer
board
in
either
of
two
positions
.
When
the plug
is
installed
/`Nwith
the
index
mark
alignedwith the
+=
DIM
markon
the
board,
a
5-volt positive
signal
applied
to
Z
AXIS
IN
(J2430)
will
cause
the
trace
to
decrease
in
intensity
(a
negative-
going
signal
will
cause
the
trace
intensity
to
increase)
.
When
plug
P2430
is
installed
with
its
index
mark
aligned
with
the
+=
BRIGHT
markon
the
board,
a
5-volt positive
signal
will
increase
the
trace
intensity
(a
negative-going
signal
will
cause
trace
intensity
to
decrease)
.
Remove
top
cover
of
the
T922R
for
access
to
Buffer
board
and
P2430
.
Service
Information-T921/T922/T922R
Fig
.
5-15
.
T922R
line-voltage
and
range
selection
.
REPACKAGING
FOR
SHIPMENT
If
the Tektronix instrument
is
to
be
shipped
to
a Tektronix
Service
Center
for
service
or
repair,
attach
a
tag
showing
:
owner
(with
address)
and
the
name
of
an
individual
atyour
firm
that
can
be
contacted
.
Include
complete
instrument
serial
number
and
a
description
of the
service
required
.
Save
and
re-use
the
package
in
which
your
instrument
was
shipped
.
If
the
original
packaging
is
unfit
for
use
or
not
available,
repackage
the instrument as
follows
:
Surround
the instrument
with
polyethylene sheeting
to
protect
the
finish
of
the instrument
.
Obtain
a
carton
of
corrugated
cardboard
of
the
correct carton
strength
and
having
inside
dimensions
of
no
less
than
six
inches
more
than the
instrument
dimensions
.
Cushion
the
instrument by
tightly
packing
three
inches
of
dunnage
or
urethanefoam
between
carton
and
instrument,
on
all
sides
.
Seal
carton
with
shipping tape or
industrial
stapler
.
The
carton
test
strength
for
the
T921
and
T922
is
275
pounds
and
for
the
T922R
is
375
pounds
.
5-
2
1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix T922 and is the answer not in the manual?

Tektronix T922 Specifications

General IconGeneral
BrandTektronix
ModelT922
CategoryTest Equipment
LanguageEnglish

Related product manuals