EasyManuals Logo
Home>Tektronix>Test Equipment>T922

Tektronix T922 User Manual

Tektronix T922
217 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
og
\O6
VOLTS/DIV
TRACE
CH
2
PRO
PROBE
'
w
m
AC
/S
GRD~~
DC
N
POSITION
S
(CHI
TRIG)
FA
0
VOLTS/DIV
Ix
tox
PROBE
1
,
z
PROBE
S
AC
~t75
GOOD
RAO
30DF
\
W
DC
AMPLIFIER
t
1982-11A
O
POSITION-Controls
the
vertical
position
of
the
crt
display
.
O
Vertical
Mode-Selects
the
vertical
amplifier
operating
mode
.
CH
1
:
Displays
only
signal
applied
to
the
CH
1
input
connector
.
This
button
mustbe
latched
in
for
X-Y
operation
.
CH
2
:
Displays only
signal
applied
to
the
CH
2
input
connector
.
DUAL
TRACE
:
Displays
CH
1
and
CH
2
input
signals
alternately
.
Chop
or
Alternate
mode
is
selected
automatically
by the
SEC/DIV
switch
.
For
SEC/DIV
switch
settings
of
1
ms
and
slower,
Chop
is
selected
.
For
settings
of
.5
ms
and
faster,
Alternate
is
selected
.
In
DUAL
TRACE
mode,
the
trigger
signal
is
derived
from
CH
1
.
When
the
DUAL
TRACE
and
CH
2
buttons
are locked
in
at
the
same
time,
the
trigger
signal
comes
from
CH
2
(instead
of
CH
1)
while
DUAL
TRACE
signals
are
displayed
.
REV
.
A,
JUNE
1976
Fig
.
2-5
.
Vertical
amplifier
front
panel
controls
.
Operating
Instructions-T921/T922/T922R
Front
Panel
(Fig
.
2-6)
C
.
TIME
BASE
SOURCE-Selects
the
source
of
the
trigger
signal
.
INT
:
Uses
a
sample
of
the
signal
displayed
on
the
crt
as a
trigger
signal
in
the
CH
1
or
CH
2
modes
.
In
DUAL
TRACE
mode,
the
trigger
signal
is
obtained
from
CH
1
.
If
CH
2and
DUALTRACE
buttons are both
latched
in,
channel
2
is
the
trigger
source
.
Line
:
Uses
a
sample
of
the
power-line
frequency
as
a
trigger
signal
.
EXT
:
Permits
triggering
on
signals
applied
to
the
X
(external
trigger)
input
connector
.
External
trigger
signals
must
be
time-related
to
the
dis-
played
signal
for
a
stable
display
.
EXT=10
:
External
trigger
signal
is
attenuated
by
a
factor
of
10
.
X-Y
:
Permits x-y
display
.
X
(horizontal)
input
is
through
the
X
input
connector
.
Y
(vertical)
input
is
normally
through
the
CH
1
orY
input
connector
(vertical
mode
CH
1
button
must
be
latched
in)
.
For
special applications,
the
Y
input
may
be
obtained
from
the
CH
2
input
connector
(CH
2
button
latched
in),
or
from
both
CH
1
and
CH
2
(DUAL
TRACE
button
latched
in)
.
tx
tox
CH
1
DUAL
2-5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix T922 and is the answer not in the manual?

Tektronix T922 Specifications

General IconGeneral
BrandTektronix
ModelT922
CategoryTest Equipment
LanguageEnglish

Related product manuals