Operating
Instructions-T921/T922/T922R
2-6
I
L
I
MODE-Selects
the
operating
mode
for
the
trigger
circuit
.
AUTO
:
With the
proper
LEVEL
control
setting,
the
sweep
can
be
triggered
by
trigger
signals
with
repetition
rates
above
about
20
Hz
.
In
the
absence
of
an adequate
trigger
signal,
or
when
the
LEVEL
control
is
misadjusted,
the
sweep
free
runs
to
provide a reference
display
.
NORM
:
Permits
triggering
on
displayed
signal
.
In
the
absence
of
an
adequate
trigger signal,
or
when
the
LEVEL
control
is
misadjusted,
the
sweep
does
not run
and
no
display
is
visible
.
Setting
SOURCE
to
LINE
position
provides
an
adequate
trigger
signal
.
TV
:
Permits
triggering
on
television
signals
.
Triggers
on
TV
field
when
SEC/DIV
switch
is
set
at
.1
ms
or
slower
.
Triggers
on
TV
line
when
SEC/DIV
switch
is
set
at
50
Ns
or
faster
.
Set the
SLOPE
switch
to
+OUT
for
sync-positive
input
signals
and
to
-IN
for
sync-negative
input
signals
.
(SLOPE-Selects
the
positive-
or
negative-going
slope
of
the
trigger
waveform
.
+OUT
:
The
sweep
can
be
triggered
from
the
positive-going
portion
of
a
trigger
signal
.
Fig
.
2-6
.
Time
base
front
panel
controls
and
connectors
.
-IN
:
The
sweep
can
be
triggered
from
the
negative-going
portion
of
a
trigger
signal
.
LEVEL-Selects
the
amplitude
point
on
the
trigger
signal
at
which
the
sweep
is
triggered
.
Usually
adjusted
for
the desired display
after
trigger
SOURCE
and
SLOPE
have
been
selected
.
(X
(External
Trigger)-Provides
input
for
external
trigger
signals
or
for
X
axis
signals
in
the
X-Y
mode
.
SEC/DIV-Selects
calibrated
sweep
rates
in
a
1-2-5
sequence
.
X1-X10
variable
control
must
be
in
the X1
detent
position
(fully
ccw)
to
read
calibrated
sweep
rates
directly
from
the
SEC/DIV
knob
.
Knob
numerals
with
N
underneath
indicates
sweep
rates
in
microseconds/division,
numerals
with
rn
underneath
indicate
sweep
rates
in
millisecon-
ds/division,
positions
with
no
symbol
under
the
numerals
indicate
sweep
rates
in
seconds/division
.
X1-X10-Provides
calibrated
sweep
rates
when
in
X1
(fully
ccw)
detent
position
.
Increases
the
horizontal
gain
by a
factor
of
10,
providing
at
least
20
ns/div
sweep
rate
in
the
X10
detent
position
(fully
cw)
with
the
SEC/DIV
knob
set
to
.2
/is
.
(POSITION-Controls
the
horizontal
position
of
the
crt
display
.
REV
.
B
APR
197
7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix T922 and is the answer not in the manual?

Tektronix T922 Specifications

General IconGeneral
BrandTektronix
ModelT922
CategoryTest Equipment
LanguageEnglish

Related product manuals