Page #56 background image
Application Notes
4. Measure the cur
rent ramp. The inductance is effectively dened by the slope
of the current ramp shown here.
Figure 22: Linear current vs. time ramp
5. Calculate the inductance using the following formula:
where:
L is the inductance in henries,
E is the voltage of the pulse generator,
dt is the change in time, and
di is the change in current.
38 TCPA300/400 Ampliers and TCP300A/400 Series Current Probes User Manual

Table of Contents

Other manuals for Tektronix TCPA300

Question and Answer IconNeed help?

Do you have a question about the Tektronix TCPA300 and is the answer not in the manual?

Tektronix TCPA300 Specifications

General IconGeneral
Accuracy±1%
Current Range30 A
Input ConnectorBNC
Output ConnectorBNC
Input Impedance0.06 Ω
Output Impedance50 Ω

Summary

General Safety Summary

Manual Conventions and Symbols

Defines terms and explains product symbols for safe operation.

Compliance Information

Safety and EMC Compliance

Details safety standards, EMC compliance, and environmental ratings.

Environmental Considerations

Product Handling and Disposal

Guidelines for recycling and responsible disposal of the product.

Preface

Manual Conventions and Service Information

Outlines manual conventions and refers to the service manual.

Getting Started

System Setup and Configuration

Guides users through initial system setup and configuration.

Amplifier and Probe Connection

Instructions for connecting amplifiers and probes to oscilloscopes.

Probe Operation and Calibration

Covers probe slide operation, degaussing, and autobalancing.

Measurement Procedures (DC & AC)

Step-by-step procedures for DC and AC current measurements.

Control Summary

Front Panel Controls and Indicators

Overview of all front panel controls, buttons, and indicators.

Probe Status and Error Indicators

Explains indicators for probe status, overloads, and errors.

Amplifier Settings and Connectors

Details settings for coupling, range, and amplifier connectors.

Reference Notes

Advanced Measurement Techniques

Covers degaussing, differential current, and AC/DC coupling.

Current Limits and Pulse Measurements

Details maximum current limits and procedures for pulse measurements.

Extending Range and Increasing Sensitivity

Methods to extend current range and boost measurement sensitivity.

Application Notes

Typical Measurement Applications

Examples of using probes for automotive, inductance, and power analysis.

Troubleshooting and Error Codes

Problem Diagnosis and Error Codes

Guides users through identifying and interpreting error codes.

Resolution Steps for Errors

Provides actions to resolve common errors and shutdown conditions.

Specifications

Performance Specifications (Warranted & Typical)

Details guaranteed and typical performance parameters.

Environmental and Physical Characteristics

Covers operating environment, dimensions, and weights.

Performance Graphs

Graphical representation of probe performance characteristics.

Glossary

Key Measurement and Operational Terms

Definitions of essential terms for understanding probe operation and measurements.

Index

Related product manuals