Introduction
▸
When operating without SIP account, SIP
server: End devices that support IP address
dialling and allow operation without SIP
account, SIP server, SIP end devices that sup-
port H.264 communication. Function should
be checked in advance by the specialist
company performing the installation.
When connected as a/b intercom station
▸
free a/b port
▸
Power supply via PoE (note the connection
options on page 74 )
Installation conditions
▸
The perfect installation height for your device
is a position that enables operating the door
intercom at a distance of 30-50 cm so the user
can easily speak into the microphone. The
same applies to the use of a camera in this
intercom station.
▸
Please keep the distance between micro-
phone and speaker as large as possible. This
gives you the best possible speech intelligi-
bility in full duplex mode.
▸
For reverse-side mounting modules
(= mounting behind an existing front wall),
ensure sufficiently large sound inlet slots
at the microphone and sound outlet slots
in front of the loudspeaker (at least 75% of
the loudspeaker membrane area for sound
outlet or 75% of the sound inlet opening on
the microphone housing). Please note our
dimensional drawings on
www.behnke-online.de/downloads
For acoustic reasons, always mount the reverse-
side mounting modules directly (without spac-
ing) and firmly to the back of your front wall.
The gaskets included in the scope of delivery
of our reverse-side mounting modules must be
installed between the reverse-side mounting
module and the rear of the front wall to ensure
unobstructed sound entry and exit.
Outdoor mounting
▸
When used on weather sides, door intercom
stations should be mounted in-wall with a
rain protection cover (please always ensure
correct installation of the supplied gasket).
▸
When mounting the door intercom stations
in surface-mounted housings, cable entry
is possible at the bottom or rear of the
surface-mounted housing. Use the fittings
supplied with the housings.
▸
The unused cable entry must be closed with
the supplied cover angle. The cable entry is
made via the PG fitting.
▸
When mounting all the stations mentioned in
these instructions in-wall, seal the top edge
of the door intercom station well to protect it
against rainwater, especially if the surface is
uneven (e.g., with silicone). Please leave the
center of the lower edge of the door intercom
station free to use as water drainage slot.
When using cover plates, the cover plate
must be sealed against the housing mounted
in-wall or the flat surface in the case of cavity
wall installations using a suitable sealing
compound or the gasket supplied.
▸
When installing in third-party pedestals or
housings respectively, suitable measures
must be taken to prevent condensation from
forming in the pedestal!