58 www.behnke-online.de
GB
Instructions SIP intercoms series 20-0001BS, 20-0014BS, 20-0016BS
Mounting
5. Behnke USB camera
▸
connect the Behnke
USB camera directly to the USB port of the
SIP intercom station.
Please note: For more information, refer to
the matching instructions for this product.
The SIP station must be de-energised when
connecting this component.
This function is only available if the intercom
station has a network connection.
6. Behnke IP camera
▸
connect the Behnke IP
camera to the switch port of the SIP intercom
station. This function is only available if the
intercom station has a network connection.
7. If required, connect the door opener to
relay 1. (Relay = voltage-free contact: only
switches the door opener circuit, does not
supply it with electrical voltage. Please use
the normally open contact). The door opener
requires its own circuit. Relay 2 is available
for further switching functions. Relay activa-
tion of relay 1 in the delivery state of the SIP
intercom station: 0#
8. Behnke hearing loop
▸
connect the Behnke
hearing loop to the corresponding port on
the basic electronics. When operating the
Behnke hearing loop, the microphone unit
requires PoE +
Important: the cable lengths of the connected
components such as loudspeaker, microphone,
keys and keypad must not exceed a length of
2.50m for all electronics types.
When extending the connecting cable, use the
suitable Behnke extension cables 20-9305-BS,
20-9311 (keypad).
Connect the hybrid intercom station to your
on-site network infrastructure or to the analogue
telephony infrastructure in compliance with the
relevant standards and regulations. For more
information, see section 4 of this manual.
Please note: PoE class0 is required!
When operating the intercom station with the
Behnke hearing loop, PoE+ is mandatory.