VII. Using the Generator
(1) Proper conditions to run the generator
(2) Run in ambient temperature between 25 ~ 100 °F or -5 ~ 40°C;
(3) A
mbient humidity below 95%;
(4) To ensure proper function of the generator, operate at altitudes up
to 1 mile above sea level. If operation is needed at higher altitudes,
a carburetor adjustment may be needed.
Standard atmospheric condition
• Ambient temperature Tr: 298k (77°F or 25°C)
• Relative air humidity Фr: 30%
• Absolute atmospheric pressure Pr: 100kPa
• Every 30% of increase in relative humidity of air will reduce the power
of generator by about 1.5%
• Every 300 m rising of ASL will reduce the power the generator by
about 4.5%
(2)Generator wiring
• When the generator is connected to a household power source as a
backup power supply, must be connected by a professional
electrician.
• After connecting the load to the generator, carefully check whether the
electrical connection is safe and reliable. An improper electrical
connection may cause generator damage or fire.
• Avoid connecting this generator to commercial power outlets.