EasyManuals Logo
Home>TOPTEK>DC Drives>TOPVERT S1-211P5

TOPTEK TOPVERT S1-211P5 User Manual

Default Icon
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
TOPVERT S1 Series
E-
18
Pr4-03
The 4th step speed of PLC Run
or MSS Run
0.00600.00 Hz
0.00
Pr4-04
The 5th step speed of PLC Run
or MSS Run
0.00600.00 Hz
0.00
Pr4-05
The 6th step speed of PLC Run
or MSS Run
0.00600.00 Hz
0.00
Pr4-06
The 7th step speed of PLC Run
or MSS Run
0.00600.00 Hz
0.00
Pr4-07
The 8th step speed of PLC Run
or MSS Run
0.00600.00 Hz
0.00
Pr4-08
The 9th step speed of PLC Run
or MSS Run
0.00600.00 Hz
0.00
Pr4-09
The 10th step speed of PLC Run
or MSS Run
0.00600.00 Hz
0.00
Pr4-10
The 11th step speed of PLC Run
or MSS Run
0.00600.00 Hz
0.00
Pr4-11
The 12th step speed of PLC Run
or MSS Run
0.00600.00 Hz
0.00
Pr4-12
The 13th step speed of PLC Run
or MSS Run
0.00600.00 Hz
0.00
Pr4-13
The 14th step speed of PLC Run
or MSS Run
0.00600.00 Hz
0.00
Pr4-14
The 15th step speed of PLC Run
or MSS Run
0.00600.00 Hz
0.00
Pr4-15
The duration of master speed
0.065500 Sec 0.0
Pr4-16
The 1st step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-17
The 2
nd
step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-18
The 3rd Step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-19
The 4th Step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-20
The 5th Step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-21
The 6th Step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-22
The 7th Step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-23
The 8th Step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-24
The 9th Step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-25
The 10th Step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-26
The 11th Step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-27
The 12th Step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-28
The 13th Step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-29
The 14th Step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-30
The 15th Step duration of PLC
Run or MSS Run
0.065500 Sec 0.0
Pr4-31
The PLC Run or MSS Run time
multiplier
110 1
Pr4-32
The PLC Run or MSS Run
operation direction of each step
00000~07FFF0forward1reverse h00000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TOPTEK TOPVERT S1-211P5 and is the answer not in the manual?

TOPTEK TOPVERT S1-211P5 Specifications

General IconGeneral
BrandTOPTEK
ModelTOPVERT S1-211P5
CategoryDC Drives
LanguageEnglish

Related product manuals