PROBLEM CAUSE SOLUTION
Machine does not
operate.
Faulty switches or wiring.
Faulty power cord.
Building circuit breaker
tripped
Contact Tornado.
Contact Tornado.
Reset breaker.
Brush motor does not
operate.
Brush motor circuit
breaker tripped.
Switch not pushed.
Loose or broken brush
belt.
Faulty switch or wiring.
Faulty brush motor.
Let motor cool and reset
brush motor breaker
button at rear of machine,
Push solution switch.
Contact Tornado
.
Contact Tornado.
Contact Tornado.
Solution pump does not
operate.
Solution pump circuit
breaker tripped.
Switch not pushed.
Faulty switch or wiring.
Faulty solution pump
motor.
Let pump cool and reset
pump breaker button at
rear of machine.
Push solution switch.
Contact Tornado.
Contact Tornado.
Vacuum motor does not
operate
Loose or broken wiring.
Faulty main power
switch.
Defective vacuum motor.
Worn carbon brushes.
Contact Tornado.
Contact Tornado.
Contact Tornado.
Contact Tornado.
Poor solution pick-up. Defective recovery tank
cover gasket.
Clogged oat shut-off
screen.
Accessory tool vacuum
hose port cover is loose
or missing.
Loose vacuum hose
cuffs.
Pulling machine too fast.
Replace gasket.
Open recovery tank
cover and clean lint off
screen.
Check vacuum hose port
cover.
Secure connections
under cover.
Slow down cleaning
process.
Uneven or no spray. Plugged spray tips.
Improper spray tip size or
spray angle.
Clogged solenoid valve.
Worn spray tips.
Solution tank low or
empty.
Faulty solution pump.
Pump needs priming.
Clean or replace tips.
Replace with proper tips
.
Contact Tornado.
Replace spray tips.
Rell solution tank.
Contact Tornado.
Prime pump by pressing
solution hose coupler
tip located at front of
machine.