HighViscosityIndex/LowPourPointAnti-wearHydraulic
Fluid,ISOVG46
MaterialProperties:
Viscosity,ASTMD445cSt@40°C44to50
cSt@100°C7.9to8.5
ViscosityIndexASTMD2270
140to160
PourPoint,ASTMD97-34°Fto-49°F
IndustrySpecications:
VickersI-286-S(QualityLevel),VickersM-2950-S
(QualityLevel),DenisonHF-0
Important:TheISOVG46Multigradeuidhas
beenfoundtoofferoptimalperformanceinawide
rangeoftemperatureconditions.Foroperation
inconsistentlyhighambienttemperatures,18°C
(65°F)to49°C(120°F),ISOVG68hydraulicuid
mayofferimprovedperformance.
PremiumBiodegradableHydraulicFluid-Mobil
EALEnviroSyn46H
Important:MobilEALEnviroSyn46Histheonly
syntheticbiodegradableuidapprovedbyToro.
Thisuidiscompatiblewiththeelastomersused
inTorohydraulicsystemsandissuitablefora
wide-rangeoftemperatureconditions.Thisuidis
compatiblewithconventionalmineraloils,butfor
maximumbiodegradabilityandperformance,the
hydraulicsystemshouldbethoroughlyushedof
conventionaluid.Theoilisavailablein19L(5
USgallons)containersor208L(55USgallons)
drumsfromyourMobilDistributor.
Important:Manyhydraulicuidsarealmost
colorless,makingitdifculttospotleaks.A
reddyeadditiveforthehydraulicsystemoilis
availablein20ml(0.67oz)bottles.Onebottle
issufcientfor15to22L(4to6USgallons)of
hydraulicuid.OrderPartNo.44-2500fromyour
authorizedTorodistributor.Thisreddyeisnot
recommendedforusewithbiodegradableuids.
CheckingtheHydraulic-Fluid
Level
Thehydraulic-uidreservoirislledatthefactory
withapproximately25.7L(6.8USgallons)ofhigh
qualityhydraulicuid.Beforeoperatingthemachine
eachday,checkthelevelofthehydraulicuid.Your
machinehasoradipstickorawhiteplasticwindow
onthefrontofthehydraulic-uidreservoir(behind
theseatontheleftside)thatisusedtocheckthe
hydraulic-uidlevel.Theuidshouldbebetweenthe
windowlinesorthedipstickmarks;ifnot,addthe
appropriateuid.
Important:Topreventsystemcontamination,
cleanthetopofthehydraulicuidcontainers
beforepuncturingthem.Ensurethatthepour
spoutandfunnelareclean.
1.Positionthemachineonalevelsurface.
Note:Ensurethatthemachinehascooled
downsothattheuidiscold.
2.Checktheuidlevelaccordingtothehydraulic
tankonyourmachine:
•Ifyourtankdoesnothaveasightwindow,
locatethedipstickonthetopofthemain
hydraulictank(Figure43)andproceedto
step3.
g234251
Figure43
1.Dipstick
•Ifyourtankhasasightwindow,checktheoil
levelthere(Figure44)andproceedtostep5.
Note:Iftheuidlevelisbetweenthe2
marksonthesightwindow,theuidlevelis
sufcient.
43