Set Temperature Activation Threshold (TWRFS models only)
The freeze sensor temperature activation threshold is adjustable from 35°F to 45°F or 2°C to 7°C.
When the air temperature reaches the threshold setting, the freeze sensor activates the receiver.
The Freeze Sensor Status indicator will turn on. The sensor system will return to the Monitor
mode when the outside air temperature rises above the sensor threshold temperature.
Select Temperature Threshold
1. Press the Setup button to display Freeze. The display will indicate the
current temperature threshold setting. See Figure 16.
Note: The display prompt will begin flashing to indicate the selected
feature is adjustable.
2. Press the Adjust button to select the preferred temperature.
Select Temperature Scale
1. Press the Setup button to display °F or °C. The display will indicate the
current temperature scale.
2. Press the Adjust button to display the alternate scale.
Congratulations!
Your Wireless RainSensor system installation is complete. Now, to take advantage of the unique
Water Conservation feature, review the information on the next page and select the level that best
suits your landscape application.
14
Figure 16
Figure 17
RainSensorAlpha7 3/10/2005 3:31 PM Page 14

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toro TWRS and is the answer not in the manual?

Toro TWRS Specifications

General IconGeneral
BrandToro
ModelTWRS
CategoryIrrigation System
LanguageEnglish

Related product manuals