E6582051
- 33 -
6. Vendor Specification Profile
Cyclic transmission of command and monitor is possible for this product by the original profile
Select the ”Telegram 100”, ”Telegram 101” or ”Telegram 102” as the profile on the configuration. Refer
to the document of network configuration tool of the PROFINET controller (PLC).
You will be able to select the command and monitor items from the following table.
Please execute these settings by the network configuration tool of the PROFINET controller (PLC).
Notes
When you use “Telegram 100”,”Telegarm101” or “Telegarm102”, the value is written to the RAM.
VF-S15/MB1 profile
Scanner input
c001
-
c006
Scanner output
c021
-
c026
0: No action
1:
fa06
(Communication command 1)
2:
fa23
(Communication command 2)
3:
fa07
(Frequency command, 0.01Hz)
5:
fa50
(Terminal output data)
6:
fa51
(FM analog output)
8:
f601
(Stall prevention level, %)
13:
acc
(Acceleration time 1, 0.1s)*
14:
dec
(Deceleration time 1, 0.1s) *
15:
ul
(Upper limit,0.01Hz)
16:
vb
(Torque boost value 1,0.1%)
17:
vlv
(Base frequency voltage 1, 0.1V)
0: No action
1:
fd01
(Status information 1)
2:
fd00
(Output frequency, 0.01Hz)
3:
fd03
(Output current, 0.01%)
4:
fd05
(Output voltage, 0.01%)
5:
fc91
(Alarm information)
6:
fd22
(PID feedback value, 0.01Hz)
7:
fd06
(Input terminal status)
8:
fd07
(Output terminal status)
9:
fe36
(VIB input, 0.01%)
10:
fe35
(VIA input, 0.01%)
11:
fe37
(VIC input, 0.01%)
12:
fd04
(Input voltage (DC detection), 0.01%)
13:
fd16
(Estimated speed (real-time value), 0.01Hz)
14:
fd18
(Torque, 0.01%)
19:
f880
(Free notes)
20:
fd29
(Input power, 0.01kW)
21:
fd30
(Output power, 0.01kW)
22:
fe14
(Cumulative operation time, 1hour)
23:
fe40
(FM terminal output monitor, 0.01%)
25:
fd20
(Torque current, 0.01%)
26:
fd23
(Motor overload factor, 0.01%)
27:
fd24
(Drive overload factor, 0.01%)
28:
fd25
(PBR overload factor, %)
29:
fd26
(Motor load factor, %)
30:
fd27
(Drive load factor, %)
31:
fe56
(Pulse train input, pps)
32:
fe70
(Drive rated current, 0.1A)
33:
fe76
(Input Watt-hour, 0.1kWh
10
f749
) **
34:
fe77
(Output Watt-hour, 0.1kWh
10
f749
) **
35:
fd83
(IGBT temperature, degree C)
* The unit of
acc
,
dec
is according to the parameter
f519
.
** The unit of
fe76
,
fe77
is according to the parameter
f749
.

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-AS3
CategoryInverter
LanguageEnglish

Related product manuals