E6581611
C-10
3
Operation Command: External Signal
Frequency Command: Setting Dial
(1) Wiring
(2) Parameter setting
Title Function Setting value

Command mode selection
0

Frequency setting mode selection 1 0 or 3
(3) Operation
Run/stop: ON/OFF input to F-CC, R-CC. (with sink logic)
F is for forward run signal and R is for reverse run signal (default setting)
Frequency setting: Turn the setting dial to set the frequency.
*1: Single-phase models are R/L1 and S/L2/N.
Ex.3
Motor
M
F
R/L1
S/L2
T/L3
U/T1
V/T2
W/T3
Forward signal
R
CC
Reverse signal
Common
MCCB
Operation panel
PB
PA/+
P
O
PC/-
*
1