12 RLC-SVX07A-EN
General Information
The Series R Unit Model Number is as follows:
Model Number RTWA070 4YA01C1DOVF
Digit Number
01
Digit Position
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8
Digit 1-2
Unit Model
RT Rotary Chiller
Digit 03
Unit Type
WWater Cooled
UCompressor Chiller (Use w/
Remote Condenser)
Digit 04
Development Sequence
A First Sequence
Digit 05, 06, 07
Nominal Capacity
070 70 Nominal Tons
080 80 Nominal Tons
090 90 Nominal Tons
100 100 Nominal Tons
110 110 N ominal Tons
125 125 Nominal Tons
Digit 08
Unit Voltage
A 200/60/3
C 230/60/3
D380/60/3
K380-415/50/3 Dual Voltage
4 460/60/3
5 575/60/3
S Special
Digit 09
Compressor Starter Type
Y Y-Delta Closed Transition
X X-Line (Across the Line)
S Special
Digit 10, 11
Design Sequence
AO First Sequence (Factory Input)
Digit 12
Evaporator Leaving Te m perature
1 Standard 40 to 65 F
2Low Temperature Process (0 to
39 F)
3 Ice-Making + 40 to 65 F
Daytime
4 Ice-Making + 0 to 39 F Daytime
S Special
Digit 13
Condenser Configuration
C Standard Length, Copper Tubes,
Std. Temp
D Long, Copper Tubes, Std. Temp
E Standard Efficiency, High Temp.,
Copper Tubes
F Long Condenser Shell, High
Temp., Copper tubes
RRemote Condenser (RTUA)
S Special
Digit 14
Agency Listing
0 No Agency Listing
3 C-UL Listing
Digit 15
Control Interface
C Deluxe without Communication
D Deluxe with Communication
L LCI-C (LonTalk)
Digit 16
Chilled Water Reset
0 No Chilled Water Reset
1 Based on Return Water
Temperature
2 Based on Outside Air Temperature
Digit 17
Compressor Volume Ratio
V Hi-Vi Application
(If Digit 12 is 3 or if Digit 13 is E,
F or R)
W Lo-Vi Application
(If Digit 12 is 1 or 3 and if Digit 13
is C or D)
Digit 18 (up to Digit 24
Miscellaneous Factory Installed
Options
DLow Ambient Lockout Sensor (1)
F Power Disconnect
N Neoprene Isolators
RRemote Display Panel
S Special Custom Option
T Condenser Water Temp
Sensors (2)
V Condenser Refrigerant Sensors (3)
Notes:
1. Either RTCA or non-RTCA
Condensers.
2. RTWA only.
3. Use only with RTUA and non-RTCA
condensers.

Table of Contents

Other manuals for Trane R Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane R Series and is the answer not in the manual?

Trane R Series Specifications

General IconGeneral
BrandTrane
ModelR Series
CategoryChiller
LanguageEnglish