TSC AUTO ID Technology Co., Ltd. 8 Copyright 2009 All Rights Reserved.
BLINE
Description
This command sets the height of the black line and the user-defined extra label feeding
length each form feed takes.
Syntax
English system (inch)
BLINE m,n
Metric system (mm)
BLINE m mm,n mm
Parameter Description
m The height of black line either in inch or mm.
0 ≤ m ≤ 1 (inch), 0 ≤ m ≤ 25.4 (mm)
n The extra label feeding length. 0 ≤ n ≤ label length
0,0 Continuous label.
Note: For metric system, there must be a space between parameter and “mm”. When
the sensor type is changed from “GAP” to “Black Mark”, please send the
“BLINE” command to the printer first.
Ex : In DOS mode,
C :\>copy con lpt1 <Enter>
BLINE 2 mm,0 <Enter>
<Ctrl>+<Z> <Enter>
Example
English system (inch)
BLINE 0.20,0.50
Metric system (mm)
BLINE 5.08 mm,12.7 mm