(figure 9)
Measurement Operation (7)
Capacitance Measurement (see figure 9)
The Meter's capacitance ranges are: 1.000nF, 10.00nF,
100.0nF, 1.000
F, 10.00 F and 100.0 F. To measure
capacitance, connect the Meter as follows:
1. Insert the red test lead or the red test clip into the
V Hz terminal and the black test lead or black
test clip into the COM terminal.
2. Set the rotary switch to
and press to
select nF measurement mode.
3. Connect the test leads or the test clips across with
the object being measured.
The measured value shows on the display.
Note
l For testing the capacitor with polarity, connect the
red test clip or red test lead to anode & black test
clip or black test lead to cathode instead.
l It takes a longer time when testing a high capacitor
value, the testing time is around 15 seconds in
100
F range.
l When capacitance measurement has been completed,
disconnect the connection between the testing leads
and the circuit under test.
Select
nF Test
blackred