Input coupling
Input impedance
Probe attenuation factor
Maximum input voltage
Time delay between channels (Typical)
DC, AC, GND
1MΩ±2% in parallel with 21pF±3pF.
1X, 10X, 100X, 1000X
400V (DC + AC Peak)
50ps
Input
Waveform interpolation
Recording length
Storage depth
Scanning range (s/div)
Accuracy of sampling
rate and delay time
Time interval (
Ƹ
T) measurement
accuracy (full bandwidth)
Linear
2 x 512K sampling point
7.5k
2ns/div-50s/div (200MHz, 150MHz);
5ns/div-50s/div (100MHz, 80MHz, 60MHz, 40MHz);
5ns/div-50s/div (25MHz)
At 1-2-5 increment.
±50ppm (any time interval ≥1ms)
Single : ± (1 sampling time interval + 50ppm x reading + 0.6ns);
> 16 average values : ± (1 sampling time interval + 50ppm x reading + 0.4ns).