EasyManuals Logo
Home>Unique>Refrigerator>UGP-10

Unique UGP-10 User Manual

Unique UGP-10
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
UGP 10
14
TROUBLESHOOTING INSTRUCTIONS &
SUGGESTED SPARE PARTS TO KEEP ON HAND
REFRIGERATOR DOES NOT COOL, CHECK LIKELY CAUSES:
1.
Burner orifice clogged. Clean. See section MAINTENANCE & SERVICE, CHAPTER 4,
Item #2. Periodic Maintenance, Items 1-9.
2.
Check to ensure refrigerator is level – (left to right and front to back)
3.
Restriction on air flow across cooling unit.
4.
Heavy frost build up on evaporator fins. Defrost.
5.
Flue baffle not inserted properly in flue tube.
6.
Improperly set thermostat. See paragraph on thermostat. In hot weather or heavy
use the setting should be closer to “Max” than usual.
7.
Burner dirty. Clean. See Section MAINTENANCE & SERVICE, CHAPTER 4,
PERIODIC MAINTENANCE
8.
LP gas pressure low at burner. Regulator pressure must not drop below 11 inches
W.C (water column) on high fire. CHAPTER 2, GAS CONNECTION
9.
Burner not located properly under the flue tube. Relocate, flame must be centered
directly into flue
10.
Burner damaged. Replace.
11.
Odours and fumes
Dislocated burner
Damaged Burner
Dirty orifice
Dirty flue tube – CHAPTER 4.