PWM control
Note
Autobalancing can be used in combination with hydronic
balancing.
PWM control is used when the Autobalancing function is active.
When installing a system with PWM control, all balancing valves can
be fully opened, the system is balanced automatically.
See Autobalancing, Page 12, for more information.
3.4
Accessories
Uponor offers a wide variety of accessories for use with the standard
portfolio.
A C DB E
F G H
CD0000140
Item Component Description
A Screws Mounting material for
thermostats T-141, T143,
T145, T146, T148, and T-149
B Uponor Smatrix S-113
(outdoor sensor S-113)
Outdoor sensor for use with
thermostats T143, T146,
T-148 and T149
C Uponor Smatrix T-X A-1XX
(wallframe T-X A-1XX)
Wall frame for covering larger
area of the wall than original
back plate. Used at installation
of thermostats T143, T145,
T146, and T148
D Uponor Smatrix Base A-14X Surface distance adaptor, if
needed, for mounting
thermostat T-149 on the wall.
E Uponor Smatrix S-114
(floor/remote sensor S-114)
Floor/remote sensor for use
with thermostats T143, T146,
T-148 and T149
F Uponor Heating/Cooling relay Relay for connecting external
voltage signal from a heating/
cooling source, such as a heat
pump, to a room controller
input.
G DIN rail DIN rail for use with Uponor
Smatrix Wave room controllers
H Uponor Smatrix Bus cable
A-145
Bus cable for use with
thermostats
3.5 Functions
Note
Setting up a system with a communication module
requires a mobile device (smart phone/tablet).
The Uponor Smatrix room controler is used to operate an underfloor
heating and/or cooling system in a house.
The room controller can also control heating via electrical underfloor
heating using an external relay.
The thermostats registered to the room controller is used to control
the actuators mounted on top of the manifold valves.
As soon as the temperature measured at a thermostat is lower
(heating mode) or higher (cooling mode) than the setpoint
temperature, a demand to change the room temperature is created
and sent to the room controller. The room controller will operate the
actuators according to current control mode and settings. This will
manage the flow to the floor loops in the room and adjust the room
temperature. Once the set temperature is reached, this information is
sent to the room controller and the demand is met.
Actuator management
Actuator management prevents too many actuators to be open at the
same time in order to reduce the peak power need. Peak current can
be reduced by delaying the opening of some actuators, as they use
most current while being opened.
Up to eight actuators in up to six rooms can be opened at the same
time. Additional actuators are queued and opened in order.
Autobalancing
Note
Autobalancing can be used in combination with hydronic
balancing.
The Uponor Smatrix room controller can operate the actuator outputs
by either on/off signals or by Autobalancing (on by default), using
pulse width modulation (PWM) signals.
Autobalancing is a function where the system calculates the actual
energy need of single rooms and adapts the output power of each
loop to its length. This means a short loop might get 20% on time
while a long loop might get about 60%.
The automatic balancing continues through the seasons and
throughout the household’s changing lifestyle and usage patterns,
removing the need of manual balancing.
This gives more even floor temperatures and faster system reaction
times with lower energy consumption than any standard on/off
system.
12
|
Uponor Smatrix Base PULSE
|
Installation and operation manual

Table of Contents

Other manuals for Uponor Smatrix Base PULSE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uponor Smatrix Base PULSE and is the answer not in the manual?

Uponor Smatrix Base PULSE Specifications

General IconGeneral
BrandUponor
ModelSmatrix Base PULSE
CategoryController
LanguageEnglish

Related product manuals