3.1.2.Serial port command mode
In this mode, W610 should works in UDP Client mode or TCP Client mode and user can send data in specified
protocol format to different server without resetting.
If user send serial data in specified protocol format from serial device to W610, W610 will parse the data and
send data after parsing to appointed server if data format is correct; if data isn’t in correct format, W610 won’t
send to server side.
Note: serial port command mode is one of transparent transmission mode and it is different from AT command
mode.
3.1.3.HTTP Client mode
In this work mode, user should configure the HTTP URL, HTTP header data, HTTP server address and HTTP
server port firstly. Serial data can be packaged into HTTP format and sent to HTTP server through W610, HTTP
server will also return data to W610.
Figure 14 HTTP Client mode
3.1.4.Modbus TCP<=>Modbus RTU mode
W610 supports Modbus TCP<=>Modbus RTU mode(doesn’t support Modbus ASCII). User just needs to configure
W610 work mode to Modbus TCP<=>Modbus RTU mode and change related parameters(port, remote IP and
some other parameters) to correct settings when user wants to use this mode.