ENGLISH
43
12 - PROGRAMMING THE CONTROL
UNIT
The configuration menu -PrG consists in a list of configurable
items; the display shows the selected item.
By pressing
i
, you will pass to the next item; by pressing
h
, you will
return to the previous item.
By pressing OK, you can view the current value of selected item and
possibly change it.
The last menu item (
FinE ) allows storing the carried out changes
and going back to the control unit normal operation.
You must exit from programming mode through this menu item if
you do not want to lose your configuration.
m WARNING: in case no operation is carried out for more
than one minute, the control unit exits from the programming
mode without saving any of your setups and changes, which
will get lost.
By holding down the
i
or
h
keys, configuration menu items will
scroll fast, until item
FinE is viewed.
In this way, you can quickly reach either the top or bottom of the list.
DISPLAY DATA FUNCTION DEFAULT MEMO
dir
Gate direction (the direction you see from the inside)
dX
dX
The gate opens rightwards
SX
The gate opens leftwards
EnSA
Energy saving function
This function is useful for reducing the energy consumption of the automation
device while in stand-by mode.
If the function is enabled, the control unit will enter ENERGY
SAVING mode under the following conditions:
30 seconds after completion of an operational cycle
30 seconds after an opening (if automatic closure is not enabled)
30 seconds after exiting the programming menu
In ENERGY SAVING mode, power to the accessories, display,
flashing lights and closure electromagnets is deactivated.
ENERGY SAVING mode is exited:
If an operational cycle is activated
If one of the keys on the control unit are pressed
no
no
Function deactivated
Si
Function activated
P.A PP
Partial opening
25
0 - 1 00
The percentage of the path the gate performs in the case of opening using
the Pedestrian Start command
t .PrE
Pre-blinking time
1 .0
0.5 - 1 00
Before any gate movement, blinker will be activated for t.PrE time, to
warn about the incoming motion (adjustable time from 0.5” to 1'00)
no
Function deactivated
t .PC h
Different closing pre-flashing time
no
0.5 - 1 00
If this parameter has a value assigned to it, the control unit will activate
pre-flashing prior to closure for the length of time set in this menu
(adjustable time from 0.5” to 1'00)
no The closing pre-flashing time corresponds to t .PrE