5.5 Set relay combinations
Enter programming mode, then press:
Step Keypad
Entry
Operation Example: Set user 12 to toggle relay when access
granted
1 1 Set Toggle Mode 1 Set Toggle Mode
2 000 – 127 Enter 3 digit User Number
000–127
012 User 12
3 0 – 3 0 = Relay Toggle
1 = Relay 1 Timed
2 = Relay 2 Timed
3 = Relay 1 and 2 Timed
0 Relay Toggle
5.6 Delete user's card
Enter programming mode, then press:
Step Keypad Entry Operation Example: Delete User 10's Card
1 6 Delete User’s Card 6 Delete User’s Card
2 000 – 127 First user to delete 010 User 10
3 000 – 127 Last user to delete 010 User 10
5.7 Delete card number
Enter programming mode, then press:
Step Keypad Entry Operation
1 7 Delete card number
2 10 digit card number 10-digit Card number with leading zeroes.
E.g. for Card 54321, enter 0000054321.
5.8 Check if user has no PIN assigned
Enter programming mode, then press:
Step Keypad
Entry
Operation
1 80 Check if user has no PIN already assigned
2 000 –
127
User 0 – 127
Keypad will flash the green LED and sound high-pitched tone if the user has NO PIN code
assigned. The keypad will flash the red LED and sound low-pitched tone if the user has a PIN
code.
ACT 5e prox – Installation and Operating Instructions ACT 5e prox Digital Keypad Programming
© Vanderbilt 2019 10 A-100512-e
25.06.2019