1 Overview
The ACT 5e prox is a simple, easy-to-use access control unit combining digital keypad and proximity
technology. The unit supports up to 128 users, each with a unique PIN code and proximity card/fob. Each
unit is contained in rugged polycarbonate housing, with stainless steel keys and potted electronics,
allowing for indoor and outdoor installation. Keypad backlighting enhances the ACT 5e prox functionality at
night or in poor light conditions.
Programming the unit is achieved via the keys, LED, and buzzer. Cards and PIN codes can be
programmed into the ACT 5e prox very quickly. Vanderbilt recommends that Users and their associated
PIN and Card are recorded in the User List at the end of the manual (see User List on page 17). Make
copies of this sheet and enter each Users details on it. This will allow users to be deleted later on, even if a
card is lost or a user forgets their PIN code.
A valid card or PIN will allow access. For maximum security, the unit may be programmed to require all
users to enter a PIN code after presenting a card.
1.1 Product specification
Number of Users 128 (128 PINs and 128 Cards)
Supply Voltage 1224V AC or DC (linear PSU)
Current Consumption 60mA (nominal), 100mA (maximum)
Operating Temperature -40 to +50°C
Door Open Time 0255s
Relay Contact Rating 5A / 50V AC
Keypad Size Flush Mount: 128 x 94 x 18.5mm
Surface Mount: 130 x 94 x 25mm
Keypad Weight 220g
Water Resistance High IP67
Construction Rugged polycarbonate housing with stainless steel keys and potted electronics.
1.1.1 Relay load
When used with inductive loads (Maglock/Strike locks) the following ratings apply.
Main relay 1.5A @ 30VDC /
1.5A @ 50VAC
The ACT 5e prox reader must be powered from a fused AC/DC PSU (1224V, 1A maximum). If the
reader is used in a manner not specified in this document, the protection provided by the reader may
be impaired.
© Vanderbilt 2019 4 A-100512-e
25.06.2019

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt ACT 5e prox and is the answer not in the manual?

Vanderbilt ACT 5e prox Specifications

General IconGeneral
BrandVanderbilt
ModelACT 5e prox
CategoryKeypad
LanguageEnglish

Related product manuals