Page #5 background imageLoading...
Page #5 background image
Using the Adjustable air outlet cover
The LED lights will illuminate over the function when selected
The air outlet cover should always be open when
the appliance is in use. Adjust the cover manually
to direct the air to the preferred setting and to
prevent the least disruption to the surroundings.
Important: When the dehumidier is rst used it will produce a signicant amount of water and the tank will need
emptying more frequently. As the room becomes drier the dehumidier collects less water and the tank takes
longer to ll.
Always switch the appliance o and unplug from the mains when removing or retting the water tank or lter and
before carrying out any maintenance or troubleshooting checks.
Using the hose for continuous drainage (optional)
Using the release handles pull either side
of the water tank and remove the water
tank from the back of the appliance .
The water tank must remain tted to the appliance when using the hose for continuous drainage. Using the drainage hose will allow
continuous emptying of the dehumidier. Water will be directed out through the hose and will not collect within the internal water tank.
The hose must be lower than the drainage port allowing the water to ow and prevent any ooding. Connect the hose to oor drain or
stand pipe making sure it is correctly secured.
Attach the drainage hose to the
water outlet. (Located behind the
drainage port).
Ret the water tank making sure the
hose lines up with the drainage port and
does not become trapped.
Using your machine Using your machine
Using the Dehumidier
Using the control panel and setting the humidity
Using the Control panel and setting the time delay
Smart Air Sensor technology
IMPORTANT:
The control panel is touch sensitive, lightly press the controls. When the machine is activated,
the digital humidity reading of the room will be displayed.
Programme Options
Using the mode button choose one of the following four options:
Fan – This programme operates the dehumidier in fan only mode (no moisture extraction, ideal for summer months when dehumidication
is not required), to circulate air in the home or a room.
Clothes dry – This programme ignores room humidity levels and any settings selected and operates full extraction on high fan mode.
This programme is best suited when drying clothes ideally in a small/medium sized room. This programme will run for 4 hours and will
automatically switch o the appliance.
Daily – This programme is specically for dehumidication within the home. The user can automatically set humidity target from
80 - 30% and will regulate to that level. The product will automatically adjust between high and low fan speed depending on the target
humidity and actual humidity level dierence.
Night – This programme is specically for dehumidication at night. The user can automatically set the humidity target from 80 – 30%
however the dehumidier will only operate in low fan for night time use. The LED light will switch o and the audio tank full will be
disabled, so as not to disturb you during the night.
The target humidity levels can be adjusted on the daily and night programs which are automatic.
The humidity can be adjusted from 80 – 30% in 5% increments. Once the room humidity meets the set level, the appliance will
automatically switch o and turn back on when needed to maintain this level. (The LED light on the front panel and the display lights
on the control panel will remain on continuously).
To make this adjustment, use the and buttons. The display wish ash to indicate this target value and will then revert back
to actual room humidity.
The timer function allows you to switch the appliance o after a set number of hours. If this is not selected the appliance will run
in continuous mode (with the exclusion of clothes drying).
Press the timer button. The display panel will then display ’00’. Using the and buttons select the required amount of time
up to a maximum of 24 hours. (The clothes drying mode can only be timed to a maximum of 12 hours). After 3 seconds of setting
the timer the display panel will revert back to displaying the humidity of the room.
To display the remaining timed hours, press the timer button and the remaining hours will then appear on the display.
Your Vax dehumidier automatically monitors the humidity in the room and adjusts the extraction rate accordingly, as well as changing the
indicator light on the front of the machine.
Blue light – indicates when the room humidity is less than 50%
Green light – indicates when the room humidity is at an ideal humidity setting of between 50% - 70%
Red light – indicates when the room humidity is very high, greater than 70%
Red ashing light means the water tank is full and will need to be emptied out.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vax DCS2V1MP and is the answer not in the manual?

Vax DCS2V1MP Specifications

General IconGeneral
BrandVax
ModelDCS2V1MP
CategoryDehumidifier
LanguageEnglish

Related product manuals