IMPORTANT: Observe all governing codes and ordinances.
It is the customer’s responsibility:
• Tocontactaqualiedelectricalinstaller.
• ToassurethattheelectricalinstallationisadequateandinconformancewithNationalElectricalCode,ANSI/
NFPA70—latestedition*,orCSAStandardsC22.1-94,CanadianElectricalCode,Part1andC22.2No.
0-M91-latestedition**andalllocalcodesandordinances.
Ifcodespermitandaseparategroundwireisused,itisrecommendedthataqualiedelectriciandeterminethat
the ground path is adequate.
A120-Volt,60Hz,AC-only,fusedelectricalsupplyisrequiredonaseparate15-ampcircuit,
DO NOT ground to a gas pipe.
Checkwithaqualiedelectricianifyouarenotsurethattherangehoodisproperlygrounded.
DO NOT have a fuse in the neutral or ground circuit.
IMPORTANT:SavethisInstallationGuideforelectricalinspectorsuse.
Therangehoodmustbeconnectedwithcopperwire/plugonly.
Therangehoodshouldbeconnecteddirectlytothefuseddisconnect(orcircuitbreaker)boxthroughexible
armoredornon-metallicsheathedcoppercable.AU.L.-orC.S.A.-listedstrainreliefmustbeprovidedateach
endofthepowersupplycable.
Wiresizes (copperwireonly)and connections mustconformwiththerating of theapplianceasspecied on
the model/serial rating label. Wire sizes must conform to the requirements of the National Electrical Code
ANSI/NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code Part 1 and C22.
2 No. 0-M91 - latest edition** and all local codes and ordinances.A U.L. - or C.S.A. - listed conduit con-
nector must be provided at each end of the power supply cable (at the range hood and at the junction box).
Copiesofthestandardslistedmaybeobtainedfrom:
*NationalFireProtectionAssociation
BatterymarchPark
Quincy,Massachusetts02269
**
CSAInternational
8501EastPleasantValleyRoad
Cleveland,Ohio44131-5575
Page8
Electrical Requirements