Malfunctions Group 30: Electrical system
30
FMI table
SAE standard
FMI Display text SAE text
0 “Value too high” Valid data, but above the normal working range
1 “Value too low” Valid data, but below the normal working range
2 “Faulty data” Intermittent or faulty data
3 “Electrical fault” Abnormally high voltage or short circuit to higher voltage
4 “Electrical fault” Abnormally low voltage or short circuit to lower voltage
5 “Electrical fault” Abnormally low current or open circuit
6 “Electrical fault” Abnormally high current or short circuit to battery negative
7 “Mechanical fault” Faulty response from mechanical system
8 “Mechanical or electrical fault” Abnormal frequency
9 “Communication fault” Abnormal updating rate
10 “Mechanical or electrical fault” Abnormally large variations
11 “Unknown fault” Unidentified fault
12 “Component fault” Faulty unit or component
13 “Faulty calibration” Calibration values outside the limits
14 “Unknown fault” Special instructions
15 Data valid but above normal operating range - least severe level
16 Data valid but above normal operating range - moderately severe level
17 Data valid but above normal operating range - least severe level
18 Data valid but above normal operating range - moderately severe level
19 Received network data in error
20 Reserved for SAE assignment
21 Reserved for SAE assignment
22 Reserved for SAE assignment
23 Reserved for SAE assignment
24 Reserved for SAE assignment
25 Reserved for SAE assignment
26 Reserved for SAE assignment
27 Reserved for SAE assignment
28 Reserved for SAE assignment
29 Reserved for SAE assignment
30 Reserved for SAE assignment
31 Condition exist