9 Maintenance
100_0202_mt_0011.fm 45
9.4 Maintenance jobs
Carry out preparations
1. Place the machine on a level surface.
2. Decommissioning the machine.
3. Deactivate machine.
4. Allow engine to cool down.
9.4.1 Check the fuel level and top off
1. Open rear protective hood.
2. Remove dirt accumulation in the area of the fuel cap.
Maintenance jobs every 1000
h/every 2
years
every 4000
h/every 4
years
every 6
years
Replace coolant.*
Replace the hydraulic oil.*
Replace the tooth belt pulley of the engine.*
Replace the hydraulic hose lines.*
*
Have this work performed by the service department of your Wacker Neuson contact partner.
CAUTION
Health risk from fuel, lubricants and coolants.
Do not inhale fuel, lubricants, coolants or vapors.
Avoid contact of skin or eyes with fuel, lubricants and coolants.
WARNING
Risk of fire and explosion from fuel and fuel vapors.
Do not smoke.
Do not refuel near open flames.
Switch off engine and allow to cool before refueling. Only refuel in a well-ventilated
vicinity.
Item Designation Item Designation
1 Limit mark 3 Fuel filter
2 Fuel cap

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson DPU90 Series and is the answer not in the manual?

Wacker Neuson DPU90 Series Specifications

General IconGeneral
BrandWacker Neuson
ModelDPU90 Series
CategoryPower Tool
LanguageEnglish

Related product manuals