Page #11 background image
Operation
11
Greenstar 2000 – 6 721 820 553 (2021/02)
4.4 Setting the flow temperature
The maximum flow temperature can be adjusted between 30 °C
and 82 °C. The current flow temperature is shown on the display.
Press the ( key.
The set maximum flow temperature is displayed.
Press arrow key or to set the required maximum flow
temperature.
Press the OK key to save. Otherwise the setting will be saved
automatically after 3 seconds.
The display shows the current flow temperature.
The ( symbol flashes in the display in heating mode. The B symbol
also appears if the burner is active.
WARNING
Risk of scalding!
This appliance is supplied with the CH control set at approximately
65 °C, a temperature that should be suitable for most installations
that comply with the current building regulations. When the boiler
switches from CH to DHW, the temperature of the hot water may
briefly exceed the DHW set point if the CH temperature is set higher
than the DHW temperature. If the CH temperature is changed to
above 65 °C, it is advisable to fit a thermostatic mixing valve (TMV) at
the point of use (e.g. before the bath hot tap or shower) to protect
vulnerable people from scalding.
4.5 Setting the DHW heating
4.5.1 Set DHW temperature
DHW temperature:
Press the * key.
The set DHW temperature is displayed.
Press arrow key or to set the required DHW temperature
Press the OK key to save. Otherwise the setting will be saved
automatically after 3 seconds.
The display shows the current flow temperature.
The * symbol flashes in the display in DHW mode. The B symbol also
appears if the burner is active.
4.5.2 Setting comfort mode or ECO mode
In comfort mode, the appliance is continually maintained at the set
temperature. This means there will be a shorter delay when drawing
DHW. However, the device will switch on even if no DHW is being drawn.
In ECO mode, heating-up to the set temperature begins as soon as the
DHW is being drawn.
In ECO mode, to reduce water usage:
Briefly open and close the DHW tap.
The water is heated once to the set temperature.
To set ECO mode: press eco until eco appears in the display.
To return to comfort mode: press the eco key until eco vanishes from
the display.
4.6 Setting summer mode
The heating pump and consequently the heating are switched off in
summer mode. The DHW supply and also the power supply for heating
controls and timer remain active.
NOTICE
Risk of the system freezing.
Frost protection is not available in summer mode.
If there is a risk of frost, exit summer mode ( Chapter 6.1).
To activate summer mode:
Press the ( key.
Keep pressing the arrow key until appears in the display.
Press the OK key to save. Otherwise the setting will be saved
automatically after 3 seconds.
] is permanently displayed.
Further notices can be found in the operating instructions for the heating
control.
4.7 Manual mode
Manual mode can be enabled to operate the boiler independent of
controls, should there be a technical issue with time and temperature
controls fitted.
To activate manual mode:
Press and hold the ( key for 5 seconds.
Check the flow temperature shown and adjust if necessary.
The flow temperature will be shown in between two hyphens,
indicating manual mode.
Fig. 8 Manual mode shown on display
Manual mode should be used for a limited time only until the time and
temperature controls are fixed.
To disable Manual Mode press and hold the ( key for 5 seconds.
0010034240-001

Other manuals for Worcester GR2300iW C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GR2300iW C and is the answer not in the manual?

Worcester GR2300iW C Specifications

General IconGeneral
BrandWorcester
ModelGR2300iW C
CategoryBoiler
LanguageEnglish

Related product manuals