EasyManuals Logo
Home>Worcester>Boiler>GR2300iW C

Worcester GR2300iW C User Manual

Worcester GR2300iW C
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
Clearances and ventilation information
13
Greenstar 2000 – 6 721 820 553 (2021/02)
7 Clearances and ventilation information
7.1 Appliance clearances
Your installer will have provided adequate space around the appliance
for operation, safety and servicing/maintenance access.
The following detail the necessary clearance around the appliance for
service and maintenance.
WARNING
Risk of injury due to damage to the boiler
Heat-producing kitchen appliances must not be operated directly
underneath the boiler.
CAUTION
Risk of damage to appliance or property
The appliance will overheat if the clearance space around the appliance
is restricted by objects.
Do not restrict this space with the addition of cupboards, shelves etc.
next to or around the appliance.
Do not store any combustible materials on or next to the appliance,
such as clothes, towels, paper or plastic bags.
Fig. 9 Appliance minimum clearances
Table 5 Appliance minimum clearances
Reduced front maintenance minimum clearances
The front servicing clearance for this appliance can be reduced to
450mm.
For installations with a front servicing clearance less than 600mm
(minimum of 450mm), the following additional criteria must be
achieved.
The bottom of the appliance case must be between 1000mm and
1500mm from the floor.
There must be at least 450mm clearance in front of the appliance to
floor level. Anything sited below the appliance must not protrude into
this clear space.
There must be at least 200mm clearance to any structure which is
sited below the appliance.
There must be at least 300mm clear space to either the left hand or
right hand side of the appliance. This clear space must be from the
required clear height above the appliance to floor level.
This clearance will not apply if the appliance is sited within
300mm of a door way and the door frame is the only obstruction.
Minimum clearances must be observed to any obstruction/ surface,
(dark shaded areas, figures 10 and 11).
Minimum clearances
Description Dimensions (mm)
X Appliance width 400
Y Appliance height 724
1)
1) Side panel height = 710mm.
Z Appliance depth 300
Maintenance
1 Overall clearance height 1094/1134
2)
2) Height for either 60/100 flue or 80/125 flue.
2 Overall clearance depth 900
3)
3) This can be reduced (refer to Reduced front maintenance minimum clearances).
3 In front of appliance 600
3)
4 Overall clearance width 410
5 Above the appliance 170/210
2)
6 Either side of appliance 5
7 Below the appliance 200
8 Compartment depth 320
4)
4) Clearance to a combustible material.
9 Appliance to removable door 20

Other manuals for Worcester GR2300iW C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GR2300iW C and is the answer not in the manual?

Worcester GR2300iW C Specifications

General IconGeneral
BrandWorcester
ModelGR2300iW C
CategoryBoiler
LanguageEnglish

Related product manuals