Top Rear View of Meter
-DC Meter Negative (BLACK) [1]
Shunt Sense Lead Load Side (GREEN) [2]
Shunt Sense Lead Battery Side (ORANGE) [3]
Battery Volt Sense (0–50 V DC
1
) (BLUE) [4]
+DC Meter Power (9.5–40 V DC) (RED) [5]
Optional Temperature Sensor Input [6]
Optional Low Battery Alarm [7]
Optional Temperature Sensor Ground [8]
SYSTEM POSITIVE
SYSTEM NEGATIVE
1234567
1234567
1234567
1234567
1234567
1234567
Twisted pair wire is used for shunt
sensing leads for noise immunity.
Battery Compartment
+
-
2 amp
Fuses
The Xantrex Link 10
works with flooded or
gel lead-acid batteries
Basic Wiring Diagram
The 500 A 50 mV
shunt senses current
in or out of your
battery.
Meter Location
+
-