6.4 Cable charts
Connection plate
791 48 01_7
6020.180
6020.090
U, V, W
L1, L2, L3
1 - 15
(2x)
WS009785A
Connections
L3
L2
L1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
U
V
W
V1
W1
U1
L3
L2
L1
BU
BU
FLS
T1
T2
T3
T4
Shrink hose GNYE
Screen as
ground conductor
Gateway / Controller
Connection
WH
WH
WH
WH
PE
Sum Alarm
Earth/Ground
continuity
WS009786A
Symbols and denominations
WS009787A
GENERAL SYMBOLS AND DENOMINATIONS
ScreenCable lead colors and marking
Motor cable
Control cores
T1 = WH
T2 = WH
T3 = WH
T4 = WH
L1 = BN
L2 = BK
L3 = GY
Stator leads
U1 = RD
V1 = BN
W1 = YE
BN = Brown
BK = Black
WH = White
OG = Orange
GN = Green
SUBCAB AWG/CSA
GC = Ground check
GNYE = Green-Yellow
RD = Red
GY = Grey
BU = Blue
YE = Yellow
Ground
Functional ground
Leakage sensor
Terminal block
FLS
6 Electrical Installation
30 Concertor
6020 Installation, Operation, and Maintenance Manual

Table of Contents