AF2ZP0CL - ACE2 - User Manual Page - 49/85
8.5 Parameter regulation
In addition to the input configuration, parameter modification is made directly by
ZAPI on customer specifications, or by the customer, making the adjustments
using the programming console.
8.5.1 Traction
The following parameters can be modified:
1) ACCELERATION 0
It specifies the motor acceleration at 0 Hz. At level 0 the acceleration is
maximum. Increasing the parameter’s level the acceleration decreases.
2) INV. ACCEL 0
It specifies the motor acceleration at 0 Hz after an inversion of direction. At
level 0 the acceleration is maximum. Increasing the parameter’s level the
acceleration decreases.
3) ACCELERATION 1
It specifies the motor acceleration at ACC PROF. FREQ 1 [Hz]. At level 0 the
acceleration is maximum. Increasing the parameter’s level the acceleration
decreases.
4) ACCELERATION 2
It specifies the motor acceleration at ACC PROF. FREQ 2 [Hz]. At level 0 the
acceleration is maximum. Increasing the parameter’s level the acceleration
decreases.
5) ACCELERATION 3
It specifies the motor acceleration at ACC PROF. FREQ 3 [Hz]. At level 0 the
acceleration is maximum. Increasing the parameter’s level the acceleration
decreases.
6) ACC PROF. FREQ 1
In correspondence to this frequency in [Hz] the acceleration is defined by the
ACCELERATION 1 parameter.
7) ACC PROF. FREQ 2
In correspondence to this frequency in [Hz] the acceleration is defined by the
ACCELERATION 2 parameter.
8) ACC PROF. FREQ 3
In correspondence to this frequency in [Hz] the acceleration is defined by the
ACCELERATION 3 parameter.