EasyManuals Logo
Home>Zapi>Inverter>ACE2

Zapi ACE2 User Manual

Zapi ACE2
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
Page - 54/85 AF2ZP0CL - ACE2 - User Manual
Minimum speed when the LIFT ENABLE switch is closed, but the accelerator
is on a minimum position.
16) MAXIMUM CURRENT
This parameter changes the maximum current of the inverter.
17) AUXILIARY TIME
Time units value (seconds). For the encoder version, is the delay when an
hydraulic steering function request is switched off.
The following table shows the minimum / maximum programmable value for
each parameter. In the table is also present the parameters resolution.
PARAMETER UNIT MIN VALUE MAX VALUE RESOLUTION
ACCELERATION 0 (*) Sec. 0,3 10 0,1
ACCELERATION 1 (*) Sec. 0,3 10 0,1
ACCELERATION 2 (*) Sec. 0,3 10 0,1
ACCELERATION 3 (*) Sec. 0,3 10 0,1
ACC PROF. FREQ 1 Hz 0 200 1
ACC PROF. FREQ 2 Hz 0 200 1
ACC PROF. FREQ 3 Hz 0 200 1
RELEASE BRAKING (**) Sec. 0,3 10 0,1
MAX SPEED LIFT Hz 5 200 1
1
ST
SPEED COARSE Hz 5 200 1
2
ND
SPEED COARSE Hz 5 200 1
3
RD
SPEED COARSE Hz 5 200 1
HYD SPEED FINE Hz 5 200 1
CUTBACK SPEED 1 %Max Sp 10 100 1
FREQUENCY CREEP Hz 0,3 2 0,1
MAXIMUM CURRENT % IMAX 0 100 1
AUXILIARY TIME Sec. 0 10 1

Table of Contents