13) The Display will show
MAIN MENU
PARAMETER CHANGE
1) ACCELER. DELAY
Seconds. It determines the acceleration ramp. The parameter sets the time
needed to speed up the traction motor from 0Hz to 100Hz.
2) RELEASE BRAKING
Seconds. It controls the deceleration ramp when the travel request is
released. The parameter sets the time needed to decelerate the traction
motor from 100Hz to 0Hz.
3) TILLER BRAKING
Seconds. It controls the deceleration ramp when the tiller is in braking
position (released). The parameter sets the time needed to decelerate the
traction motor from 100Hz to 0Hz
4) INVERS. BRAKING
Seconds. It controls the deceleration ramp when the direction switch is
inverted during travel. The parameter sets the time needed to decelerate the
traction motor from 100Hz to 0Hz.
5) DECELERATION BRAKING
Seconds. It controls the deceleration ramp when the accelerator has turned
down but not completely released. The parameter sets the time needed to
decelerate the traction motor from 100Hz to 0Hz.
6) SPEED LIMIT BRK
Seconds. It controls the deceleration ramp when a speed reduction has been
activated. The parameter sets the time needed to decelerate the traction
motor from 100Hz to 0Hz.
7) CURVE BRAKING
Seconds. It controls the deceleration ramp when the curve cutback input
becomes active. The parameter sets the time needed to decelerate from
100Hz to 0Hz.
8) MAX SPEED FWD
Percentage. It determines the maximum speed in forward direction.
9) MAX SPEED BWD
Percentage. It determines the maximum speed in backward direction.
10) CUTBACK SPEED 1
Typically from 10% to 100%. It determines the percentage of the max speed
applied when the cutback switch 1 (CUTBACK on CNA#11 in AmpSaab
connector, CNA#6 in AmpSeal) is active. When set to 100% the speed
reduction is ineffective.
11) CUTBACK SPEED 2
Typically from 10% to 100%. It determines the percentage of the max speed
applied when the cutback switch 2 is active. When set to 100% the speed
reduction is ineffective.
AEQZP0BA – COMBI AC1 - User Manual Page - 45/86