9.5.5 Config menu “TESTER ” functions list
1) MOTOR CURRENT
Ampere. It is the current in the motor controlled by the slave of combiac1.
2) MOTOR VOLTAGE
It is the voltage of the motor controlled by the slave of combiac1, expressed
in percentage of the maximum voltage.
3) MOTOR POWER
Watt. Estimate value of the traction motor power. This parameter is used by
Slave µC in order to carry out safety checks on traction functions (managed
by Master µC).
4) ENCODER
Hz. Speed of the traction motor. This parameter is used by Slave µC in order
to carry out safety checks on traction functions (managed by Master µC)
5) SLIP
Hz. Estimate of traction motor slip. This parameter is used by Slave µC in
order to carry out safety checks on traction functions (managed by Master
µC).
6) MOTOR TEMPERATURE
°C. Measure of the pump motor temperature.
7) LIFTING CONTROL
Volt. Measure of the lift/lower potentiometer input (signal CPOTLIFT: CNA#25
in AmpSaab connector, CNA#30 in AmpSeal connector).
8) HANDLE/SEAT SW
On/off: it determines if the TILLER input is active or not (CNA#7 in AmpSaab,
CNA#20 in AmpSeal).
9) DIGITAL INPUT 1
On/off : it determines if the input 1 is active or not (Lowering switch, CNA#5 in
AmpSaab, CNA#20 in AmpSeal).
10) DIGITAL INPUT 2
On/off : it determines if the input 2 is active or not (Speed Reduction#1
switch, CNA#11 in AmpSaab, CNA#6 in AmpSeal).
11) DIGITAL INPUT 3
On/off : it determines if the input 3 is active or not (Forward switch, CNA#18
in AmpSaab, CNA#32 in AmpSeal).
12) DIGITAL INPUT 4
On/off : it determines if the input 4 is active or not (Reverse switch, CNA#19
in AmpSaab, CNA#31 in AmpSeal).
13) DIGITAL INPUT 5
On/off : it determines if the input 5 is active or not (CNA#20 in AmpSaab,
CNA#19 in AmpSeal).
AEQZP0BA – COMBI AC1 - User Manual Page - 55/86