14) DIGITAL INPUT 6
On/off : it determines if the input 6 is active or not (Belly switch, CNA#33 in
AmpSaab, CNA#7 in AmpSeal).
15) DIGITAL INPUT 7
On/off : it determines if the input 7 is active or not (Speed Reduction #3
switch, CNA#34 in AmpSaab, CNA#35 in AmpSeal).
16) DIGITAL INPUT 8
On/off : it determines if the input 8 is active or not (Deadman switch, CNA#35
in AmpSaab, CNA#17 in AmpSeal).
17) DIGITAL INPUT 9
On/off : it determines if the input 9 is active or not (H&S switch, CNA#6 in
AmpSaab, CNA#29 in AmpSeal).
18) DIGITAL INPUT 13
On/off : it determines if the input 13 is active or not (Horn switch, CNA#21 in
AmpSaab).
19) SET POINT EVP
This parameter shows the setpoint of EVP valve.
20) EV1
Show the percentage of voltage applied to Ev1 valve.
21) EV2
On/Off: determines if the valve is open or closed.
22) EV3
On/off: determines if the valve is open or closed.
23) EV4
On/off: determines if the valve is open or closed.
24) EV5
On/off: determines if the valve is open or closed.
25) EV6
On/off: determines if the valve is open or closed.
26) EV7
On/off: determines if the valve is open or closed.
Page - 56/86 AEQZP0BA – COMBI AC1 - User Manual