10) MIN EVP
0 to 100. This parameter determines the minimum voltage applied on the
EVP when the position of the potentiometer is at the minimum. This
parameter is not effective if the EVP is programmed like a On/Off valve.
11) MAX EVP
0 to 100. This parameter determines the maximum voltage applied on the
EVP when the position of the potentiometer is at the maximum. If the EVP is
programmed like a On/Off valve this parameter determines the fixed voltage
applied on the electrovalve coil.
12) EVP OPEN DELAY
In seconds. It defines the opening ramp of the evp electrovalve when related
output is set as Analog (refer to Set Option menu).
13) EVP CLOSE DELAY
In seconds. It defines the closing ramp of the evp electrovalve when related
output is set as Analog (refer to Set Option menu).
14) EV1 OPEN DELAY
In seconds. It defines the opening ramp of the evp1 electrovalve, when
related output is set as Analog (refer to Set Option menu).
15) EV1 CLOSE DELAY
In seconds. It defines the closing ramp of the evp1 electrovalve, when related
output is set as Analog (refer to Set Option menu).
PROGRAMMED LEVEL
PARAMETER UNIT
0 1 2 3 4 5 6 7 8 9
PUMP IMAX % From 50% to 100% of IMAX, resolution of 5%
PUMP ACC. DELAY Sec. From 0 to 10 sec., resolution of 0.1
PUMP DEC. DELAY Sec. From 0 to 10 sec., resolution of 0.1
SPEED LIMIT % From 0% to 100%, resolution of 1%
CREEP SPEED % From 0% to 100%, resolution of 1%
COMPENSATION % From 0% to 100%, resolution of 1%
HYD SPEED FINE % From 0% to 100%, resolution of 1%
HYDRO COMPENSATION % From 0% to 100%, resolution of 1%
CUTBACK SPEED % From 0% to 100%, resolution of 1%
MIN EVP % From 0% to 100%, resolution of 0.1%
MAX EVP % From 0% to 100%, resolution of 0.1%
EVP OPEN DELAY Sec. From 0 to 25.5 sec., resolution of 0.1
EVP CLOSE DELAY Sec. From 0 to 25.5 sec., resolution of 0.1
EV1 OPEN DELAY Sec. From 0 to 25.5 sec., resolution of 0.1
EV1 CLOSE DELAY Sec. From 0 to 25.5 sec., resolution of 0.1
AEQZP0BA – COMBI AC1 - User Manual Page - 53/86