Operating Your Appliance
Demonstration Mode
In this mode, the compressor and fans never turn on but all other functions remain enabled. When in
Demonstration Mode, the “R” indicator light will slowly blink indicating it is in Demonstration Mode.
To enable or disable Demonstration mode, hold Power Button and tap Decrease Temperature Button
twice.
Temperature Alarm
If the interior temperature is higher than 73ºF (23ºC), “HI” is shown on the temperature control panel
and the temperature alarm will sound continuously after one hour. This indicates that the inner
temperature is too high. If the inner temperature is lower than 28ºF (-2ºC) on the wine cooler, “LO” is
shown on the temperature display panel and the temperature alarm will sound continuously after 15
minutes. For beverage coolers, the alarm will trigger if the temperature is lower than 25ºF (-4ºC). If
one of these situations occur, please reference the troubleshooting section for support.
Defrosting
The cooler is designed with an automatic defrost system. However, on colder settings, some frost may
build up. Additionally, the more humid the ambient conditions, the more frost may build up. Keep the
door closed as much as possible and avoid opening the door unnecessarily to minimize frost build-up.
If frost is preventing the door from closing properly, you may need to power the unit o until the frost
melts (possibly up to 24 hours). Use a soft absorbent towel to dry the unit.
Never attempt to remove frost with a sharp object.
WARNING