10
www.zephyronline.com
1. Remove (4) screws attaching motor to hood
body.
2. Remove knock out plate A & B for rectangular
ducting or knock out plates B & C for round
ducting.
3. Attach rectangular or round duct collar to interior
of hood body by (4) screws.
This range hood is equipped standard with a 8” round vertical duct option. To convert from 8” round vertical to 8”
round horizontal ducting or 3-1/4” x 10” rectangular horizontal ducting please following the instructions below.
VERTICAL TO HORIZONTAL DUCTING CONVERSION
4. Attach rear ducting brackets to motor by (4)
screws.
Installation – Horizontal Ducting Conversion