EasyManuals Logo

Zte ZXR10 2918E-PS User Manual

Zte ZXR10 2918E-PS
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #251 background image
Chapter6Maintenance
RXPAIR:
CableTestPassed.Noproblemfound.
CableLengthisunknown.
TXPAIR:
CableTestPassed.Noproblemfound.
CableLengthisunknown.
Example2
zte(cfg)#showvctport8
CableTestResultforPort8
RXPAIR:
CableTestPassed.Cableisopen.
Approximately7metersfromthetestedport.
TXPAIR:
CableTestPassed.Cableisopen.
Approximately6metersfromthetestedport.
6.3CommonFaultHandling
6.3.1IntroductiontoCommonFault
Faultincludeshardwarefaultandsoftwarefault.Forhardwarefault,ifwecancorrectly
locate,thiskindoffaultisremovedbychanginghardware.Forsoftwareandthefaultof
theconguration,thecorrectoperationcanbeusedtoresolvetheproblem.
Duringtheprocessofhandlingfault,accordingtothepreviouschapter,checkwhetherthe
congurationofthedeviceiscorrect,thecableofthedeviceiscorrectandtheenvironment
ofthedeviceissatisfying.
6.3.2TheConfigurationbyConsolePortFails
FaultPhenomenon
Thecongurationbyconsoleportfails.
RelatedComponentCheck
Congurationcable,HyperT erminalserialport,switchConsoleport
FaultAnalysisandLocation
1.Thecongurationcableconnectionisnotcorrect.
2.HyperTerminalserialportattributecongurationiswrong,terminalserialporthasfault.
3.Theconsoleportoftheswitchhasfault.
6-3
SJ-20120409144109-002|2012-07-02(R1.0)ZTEProprietaryandCondential

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2918E-PS and is the answer not in the manual?

Zte ZXR10 2918E-PS Specifications

General IconGeneral
MAC Address Table Size8K
VLANs4K
Jumbo Frame9K
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
PoE802.3af/at
Power SupplyAC 100-240V
Dimensions (W x D x H)440mm x 44mm

Related product manuals