EasyManuals Logo

Zte ZXR10 2918E-PS User Manual

Zte ZXR10 2918E-PS
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
ZXR102900ESeriesCongurationGuide
CommandFunction
zte(cfg)#terminallogtoFileSavestheloginRAMtoFLASH.
zte(cfg)#terminallogtimer{enable|disable|
interval<1-720>}
Setsautomaticsavingofloginformation.
zte(cfg)#setbootpasswordto<string>Setsthepasswordforloggingintobootmode
zte(cfg)#setbootpasswordclearDeletesthepasswordforloggingintobootmode
zte(cfg)#setfanmode{auto|manual}Setsthefanoperatingmode.
zte(cfg)#setfanspeedSetsthefanoperatingspeed.
zte(cfg)#readconfig<filename>Readsthelocalleonthedeviceastheconguration.
zte(cfg)#settemperature-alarm<0-100>Setsthethresholdforovertemperaturealarmsontheswitch.
zte(cfg)#clearterminal-logClearsloginformation.
zte(cfg)#terminallogmodule{all|arp-inspection|d
hcp|radius|AAA}{off|on}
Allows/forbidswritinglogsofamodule.
zte(cfg)#terminalmonitormodule{all|
arp-inspection|dhcp|radius|AAA}{off|on}
Allows/forbidsprintingreal-timealarmlogsofamodulefor
theterminal.
listinclude<string>(allcongurationmodes)Displaysthecommandsincludingaspecicstring.
showterminalloginclude<string>(allconguration
modes)
Displaysalarmloginformationincludingaspecicstring.
showreset-time(allcongurationmodes)DisplaysswitchConsoleautomaticlogouttimeconguration.
showline-vty(allcongurationmodes)DisplaysTelnetuserlogintimeouttimeconguration.
showloginauth(allcongurationmode)Displaysloginauthenticationmode.
showadminauth(allcongurationmodes)
Displaysmanagementauthenticationstateandauthentication
mode.
showterminal(allcongurationmodes)Displaysterminallogcongurationinformation.
showterminallog(allcongurationmodes)DisplaystheterminalloginformationinRAM.
showuser(allcongurationmodes)
Displaystheuserconguredontheswitchandcurrentlogin
userinformation.
showversion(allcongurationmodes)Displaysthesysteminformation.
showrunning-config[{include|begin}<string>](all
congurationmodes)
Displaysallcurrentsystemnon-defaultconguration.
showstart-config(allcongurationmodes)
Displaysallnon-defaultcongurationwhensystemiswritten
atlast.
showdate-time(allcongurationmodes)Displaysthecurrentdateandtime.
showreboot-time(allcongurationmodes)Displaysautomaticrebootconguration.
showcpu(allcongurationmodes)DisplaysCPUusageatthedurationof5s,30sand2m.
4-4
SJ-20120409144109-002|2012-07-02(R1.0)ZTEProprietaryandCondential

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2918E-PS and is the answer not in the manual?

Zte ZXR10 2918E-PS Specifications

General IconGeneral
MAC Address Table Size8K
VLANs4K
Jumbo Frame9K
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
PoE802.3af/at
Power SupplyAC 100-240V
Dimensions (W x D x H)440mm x 44mm

Related product manuals