EasyManuals Logo

Zte ZXR10 8900E series User Manual

Zte ZXR10 8900E series
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #127 background imageLoading...
Page #127 background image
ZXR10 8900E series Core Switch Product Description
ZTE Confidential Proprietary
© 2013 ZTE CORPORATION. All rights reserved.
117
7.2.2 Monitoring and Maintenance
ZXR10 8900E supports multiple types of equipment monitoring, management and
maintenance. These services enable the device to take correct action in any abnomal
cicurmstance. Also, they can offer all parameters related to equipment operation.
7.2.2.1 Equipment Monitoring
There are indicators on power supply unit, fan, MPU and all sorts of interface card to
show the operating status of the components.
MPU hot-swappable implementation and switchover event are recorded.
When fan, power supply unit and temperature are wrong, sound alarm and software
alarm will be generated.
Check the cross-division feature of the version when the system is running.
Check module temperature automatically in the course of running the system.
Provide temperature control and software alarm services.
The system monitors the running status of the software. If serious abnormity
happens, line card will be restarted and the MPU will be switched over.
7.2.2.2 Equipment Management and Maintenance
The command line provides flexible online help.
Provide hierarchical user authority management and command.
Support information center. Provide unified management of log, alarm and
debugging information.
Support switch cluster management. Provide unified maintenance management
channel for multiple devices.
Query basic information of MUP, interface card and optical module via CLI
command line.
Enable the query of multiple information, including version, component status,
environment temperature, CPU and memory utilization.
Support one-touch device information collection. The command result can either be
displayed on the device or input in the file. Hardware environment, software
information, version information, data configuration, real-time device running status
and protocol information can be displayed. This information can be totally or partially
exported.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 8900E series and is the answer not in the manual?

Zte ZXR10 8900E series Specifications

General IconGeneral
SeriesZXR10 8900E
CategorySwitch
Storage Temperature-40°C to 70°C
Relative Humidity5% to 95% (non-condensing)
TypeModular switch
Port DensityUp to 576 x 10GE ports, 144 x 40GE ports
Ports10GE, 40GE, 100GE
RedundancyRedundant power supplies, fans, and control modules
Network ProtocolsIPv4/IPv6, MPLS, VXLAN
ManagementCLI, SNMP, Web
Power SupplyAC/DC
WeightVaries by configuration
Operating Temperature0°C to 45°C
Power ConsumptionVaries by configuration
Slots8