35266HSH MODBUS TRANSMITTER | PRESSURE/TEMPERATURE MULTIVARIABLE | OI/266HSHMT-EN REV. A

instructions included with the handheld terminal.

according to customer specifications for the measuring













purposes.

software for the steps required to install the operating
tool. The most important parameters can be set via the


testing the transmitter.

means of an internal database.







7.13 Configuration with the graphical user
interface (DTM) - System requirements






relevant operating instruction.
7.14 Standard and Advanced HART: functionality
266 Pressure Transmitters can be codified with:





  
Configuration via HMI On board Not available
SIL certified On board Not available
PILD On board On board
Trend On board Not available
Totalizer On board On board
Service Port On board Not available
Electronic replacement On board Not available
7.15 

Description

date
From To
7.1.11 First release 09/2009
7.1.11 7.1.12
Bug Fixing:
microbar and millitor units added
HART command 35 bug fixed. By HART
specificaiton #35 unit should not be
set pv unit
if the local indicator was not mounted,
only one operation via push buttons
was performed
MWP diagnosis classification become
Maintenance instead of
Off-Specification
Improvements:
replacement functionality improved
internal improvements to reduce
factory configuration
more/stronger checks about process
variables goodness
HART response time reduced (30%)
06/2010
7.1.12 7.1.14
Improvements:
factory configuration speeded up
service detailed diagnosis
implemented
01/2011
7.1.14 7.1.15
Bug Fixing:
sensor trimming via local display was
performend only in kPa
diagnosis “Replace Error” no more
shown
unit strings on display (Nm3, bbl, t)
were wrong
New Features:
new language (French & Spanish) on
local indicator
sensor polarity invertion
01/2013
7.1.15 7.2.1 HART 7 implementation 11/2015
7.1.15
7.2.1
7.1.16
(HART 5)
7.2.2
(HART 7)
New Features:
Temperature alarm enabled by user
oscillation alarm control
switching of alarm for wrong power
supply
10/2018
7.15
7.16

Table of Contents

Other manuals for ABB 266HSH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB 266HSH and is the answer not in the manual?

ABB 266HSH Specifications

General IconGeneral
BrandABB
Model266HSH
CategoryTransmitter
LanguageEnglish

Related product manuals